Battery runtime
Hours = Ah × V × DoD × Efficiency ÷ WattsA 12 V 100 Ah lead-acid battery at 50% depth of discharge, through a 90% efficient inverter, runs a 100 W load for 100 × 12 × 0.5 × 0.9 ÷ 100 = 5.4 hours.
Inverter backup, solar, RV, UPS and more
This battery runtime calculator shows how long your battery will last under any load, or what size battery you need for the backup time you want. It accounts for battery chemistry, depth of discharge, inverter losses and series or parallel banks.
Formulas
Battery runtime depends on how much energy the battery stores, how much of it you can safely use, the losses on the way and how much power your appliances draw.
Hours = Ah × V × DoD × Efficiency ÷ WattsA 12 V 100 Ah lead-acid battery at 50% depth of discharge, through a 90% efficient inverter, runs a 100 W load for 100 × 12 × 0.5 × 0.9 ÷ 100 = 5.4 hours.
Ah = Watts × Hours ÷ (V × DoD × Efficiency)To run 1,000 W for 1 hour from a 12 V LiFePO4 bank at 90% depth of discharge and 90% efficiency, you need 1,000 × 1 ÷ (12 × 0.9 × 0.9) = 103 Ah.
Wh = Ah × VoltsWatt-hours let you compare batteries of different voltages. A 12 V 200 Ah battery and a 24 V 100 Ah battery both store 2,400 Wh.
Series adds volts, parallel adds AhTwo 12 V 100 Ah batteries in series make a 24 V 100 Ah bank. In parallel they make a 12 V 200 Ah bank. Both store 2,400 Wh.
Know your load. Add up the watts on each appliance label. If only amps are shown, convert them with the watts to amps calculator.
Reference
Approximate runtimes for popular 12 V battery sizes through a 90% efficient inverter. Lithium batteries last much longer because more of their capacity is usable.
| 12 V battery | 50 W | 100 W | 200 W | 300 W | 500 W | 1,000 W |
|---|---|---|---|---|---|---|
| 50 Ah | 5 h 24 min | 2 h 42 min | 1 h 21 min | 54 min | 32 min | 16 min |
| 100 Ah | 10 h 48 min | 5 h 24 min | 2 h 42 min | 1 h 48 min | 1 h 5 min | 32 min |
| 150 Ah | 16 h 12 min | 8 h 6 min | 4 h 3 min | 2 h 42 min | 1 h 37 min | 49 min |
| 200 Ah | 21 h 36 min | 10 h 48 min | 5 h 24 min | 3 h 36 min | 2 h 10 min | 1 h 5 min |
| 300 Ah | 32 h 24 min | 16 h 12 min | 8 h 6 min | 5 h 24 min | 3 h 14 min | 1 h 37 min |
| 12 V battery | 50 W | 100 W | 200 W | 300 W | 500 W | 1,000 W |
|---|---|---|---|---|---|---|
| 50 Ah | 9 h 43 min | 4 h 52 min | 2 h 26 min | 1 h 37 min | 58 min | 29 min |
| 100 Ah | 19 h 26 min | 9 h 43 min | 4 h 52 min | 3 h 14 min | 1 h 57 min | 58 min |
| 150 Ah | 29 h 10 min | 14 h 35 min | 7 h 17 min | 4 h 52 min | 2 h 55 min | 1 h 27 min |
| 200 Ah | 38 h 53 min | 19 h 26 min | 9 h 43 min | 6 h 29 min | 3 h 53 min | 1 h 57 min |
| 300 Ah | 58 h 19 min | 29 h 10 min | 14 h 35 min | 9 h 43 min | 5 h 50 min | 2 h 55 min |
Chemistry
Draining a battery too deeply shortens its life. These are typical safe depths of discharge and cycle lives for daily use.
| Battery type | Usable capacity | Typical cycle life | Best for |
|---|---|---|---|
| Flooded or tubular lead-acid | 50% | 500 to 1,200 cycles | Home inverters, budget backup |
| AGM lead-acid | 50% | 300 to 700 cycles | UPS units, sealed spaces |
| Gel lead-acid | 50 to 60% | 500 to 1,000 cycles | Deep cycle use, hot climates |
| LiFePO4 lithium | 80 to 100% | 2,000 to 6,000 cycles | Solar, RV, daily cycling |
| Lithium-ion NMC | 80% | 1,000 to 2,000 cycles | Portable power stations, EVs |
Why ours
Most battery calculators divide capacity by load and stop. That overstates runtime, sometimes by half.
Depth of discharge is set for your battery chemistry, so lead-acid and lithium results reflect what you can actually use.
Find how long a battery lasts, or flip the question and find the battery size you need for a target backup time.
AC appliances lose energy in the inverter. Turn it on for AC loads or off for DC devices like fridges in campervans.
Model several batteries in series or parallel and see the bank voltage, capacity and current at a glance.
Get alerts for high discharge rates that cut lead-acid capacity and for deep discharges that shorten battery life.
A live chart shows how runtime changes as you add or remove load, so you can decide what to keep on during an outage.
Guide
Have your battery label and appliance wattages handy. Results update as you type.
Pick How long it lasts for runtime, or Battery size needed for a target backup time.
The usable percentage fills in automatically. Adjust it if your manufacturer recommends a different depth of discharge.
Add the amp-hour rating and voltage from the label, plus how many batteries you have and how they are connected.
Type the total watts or tap the quick-add buttons for common appliances. Set the inverter efficiency for AC loads.
Check the runtime, warnings and curve, then copy or share your result.
Benefits
Anyone who depends on stored power can plan better with accurate runtime numbers.
Know how long fans, lights and the TV will run during a power cut, and whether a second battery is worth it.
Size a battery bank for overnight use and compare it with your panel output from the solar rooftop calculator.
Plan how long you can stay off-grid before running the engine or a generator, then size one with the generator size calculator.
Make sure CPAP machines, routers and security systems stay powered through the night when the grid goes down.
FAQ
A 12 V 100 Ah battery stores 1,200 Wh. With a lead-acid battery used to 50% and a 90% efficient inverter, it runs a 100 W load for about 5.4 hours. A 12 V 100 Ah LiFePO4 battery used to 90% runs the same load for about 9.7 hours.
Multiply the battery amp-hours by its voltage to get watt-hours, then multiply by the usable depth of discharge and the inverter efficiency. Divide the result by your load in watts to get runtime in hours.
Depth of discharge is the percentage of a battery’s capacity you use before recharging. Lead-acid batteries last longest when used to about 50%, while lithium iron phosphate batteries can safely use 80% to 100% of their capacity.
Through a 90% efficient inverter you need about 1,111 Wh of usable energy. That is roughly 185 Ah of 12 V lead-acid at 50% depth of discharge, or about 103 Ah of 12 V LiFePO4 at 90% depth of discharge.
A 12 V 150 Ah lead-acid inverter battery running a 300 W load lasts about 2.7 hours if used to 50%. Many home inverters drain batteries to about 80%, which stretches runtime to about 4.3 hours but shortens battery life.
Connecting batteries in series adds their voltages while the amp-hours stay the same. Connecting them in parallel adds their amp-hours while the voltage stays the same. Total stored energy in watt-hours is the same either way.
Batteries lose capacity with age and in cold weather, lead-acid batteries deliver less at high discharge rates because of the Peukert effect, and inverters draw some standby power even with no load. Plan for 10% to 20% less runtime to be safe.
Yes. Inverters are typically 85% to 95% efficient, so part of the battery energy is lost as heat. They also draw standby power, often 10 to 30 watts, whenever they are switched on.
Multiply amp-hours by the battery voltage. A 12 V 100 Ah battery stores 1,200 Wh, and a 48 V 100 Ah battery stores 4,800 Wh. Watt-hours make it easy to compare batteries with different voltages.
Use the battery runtime calculator before you buy a battery, inverter or solar system, then size the rest of your backup setup with our related tools.
Calculate my runtimeResults are estimates. Real runtime varies with battery age, temperature, discharge rate and inverter standby power.